ZCL series Low Temperature Chillers,a new generation refrigeration unit,specially designed by CNCEN, and are widely used in medicine industry,chemical industry,bioengineering etc.The temperature is adjustable in the range of -30℃~+40℃.
Technical parameter:
Technical parameters of ZCL-AL series of air cooled low temperature chillers (When T=-10℃) | |||||||||||
Model | ZCL-3AL | ZCL-5AL | ZCL-8AL | ZCL-10AL | ZCL-12AL | ZCL-15AL | ZCL-20AL | ZCL-25AL | ZCL-30AL | ZCL-40AL | |
Nominal cooling capacity | KW | 2.92 | 4.68 | 7.83 | 10.98 | 13.59 | 16.47 | 21.96 | 23.4 | 27.18 | 34.2 |
50HZ/60HZ | 3.5 | 5.61 | 9.39 | 13.17 | 16.3 | 19.76 | 26.35 | 28.08 | 32.61 | 41.04 | |
kcal/h | 2514 | 4023 | 6732 | 9440 | 11684 | 14160 | 18881 | 20119 | 23369 | 29405 | |
50HZ/60HZ | 3012 | 4823 | 8078 | 11328 | 14014 | 16993 | 22657 | 24143 | 28043 | 35286 | |
Total input power | KW | 3.18 | 4.86 | 7.25 | 9.4 | 10.9 | 13.47 | 18.8 | 22.55 | 28.5 | 36 |
Power | 3 φ380V/50HZ | ||||||||||
Refrigerant | Type | R22(R404A/R507) | |||||||||
Control method | Expansion valve | ||||||||||
Compressor | Type | Hermetic piston type(scroll type) | |||||||||
Power(KW) | 2.25 | 3.75 | 6 | 7.5 | 9 | 11.25 | 15 | 18 | 22.5 | 30 | |
Condenser | Type | Finned copper tube+low noise outer rotor fan | |||||||||
Evaporator | Type | Shell-and-tube-type | |||||||||
Chilled fluid flow(m3/h) | 1.69 | 2.71 | 4.54 | 6.36 | 7.88 | 9.55 | 12.73 | 13.57 | 15.76 | 19.83 | |
Inlet and outlet Pipe(inch) | 1" | 1" | 1" | 1 1/2" | 1-1/2" | 2" | 2-1/2" | 2-1/2" | 2-1/2" | 3" | |
Water pump | Power(kw) | 0.75 | 0.75 | 0.75 | 1.1 | 1.1 | 1.5 | 2.2 | 2.2 | 4 | 4 |
Lift(m) | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 25 | |
Safety protection | Compressor over temperature,over current,high and low pressure,over temperature,flow switch,phase sequence,phase-missing,exhaust Overheating,antifreezing. | ||||||||||
Dimension | L*W*H(mm) | 900*700*1060 | 1250*750*1100 | 1360*800*1400 | 1450*850*1400 | 1550*850*1410 | 1750*850*1560 | 2000*1050*1600 | 2450*1100*1450 | 2600*1200*1750 | 2000*2000*1590 |
Weight | Kg | 135 | 175 | 310 | 450 | 530 | 750 | 835 | 920 | 1080 | 1125 |
Note:
1.Nominal cooling capacity calculated Inlet/outlet chilled fluid temperature : -5℃/-10℃.Inlet/outlet cooling air temperature:30℃/38℃.
2. Working condition:The temperature range of chilled fluid is from -10℃ to 10℃.Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃. It is better to run the chiller while the ambient temperature at or below 35℃.
3.Other Voltages 115V, 208V, 220V, 230V,460V (Single and Three Phase) 50/60HZ Available, which need to made accordingly.
We reserve the right to modify the above information without further notice.